Honda Accord: Change Lever Clearance Inspection
1. Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.
Standard: 0.05-”0.25 mm (0.002-”0.010 in)
Service Limit: 0.50 mm (0.020 in)
2. Measure the groove width of the change lever.
- If the groove width is not within the standard, replace the change lever.
- If the groove width is within the standard, replace the select lever.
Standard: 15.00-15.10 mm (0.591-0.594 in)
Reverse Shift Fork Clearance Inspection
1. Measure the clearance between the reverse Idler gear
(A) and the reverse shift fork (B) with a feeler gauge
(C). If the clearance exceeds the service limit, go to
step 2.
Standard; 0.20-0.59 mm ...
Change Lever Assembly Disassembly/Reassembly
NOTE: Prior to reassembling, clean all the parts in solvent, dry them, and
apply grease to contact surfaces as shown. Do
not wash the rubber parts with solvent.
...
See also:
Under-floorTWC Removal/Installation
1. Raise the vehicle on a lift.
2. Remove the exhaust pipe hangers (A).
3. Remove the under-floor TWC (B).
4. Install the parts in the reverse order of removal with
new gaskets (C) and new s ...